20 kV High-Voltage Cable Assemblies

50 Ohm Cable Assemblies with 20 kV, 10 kV, SHV and MHV Connector Configurations
Bracke Manufacturing offers 50 Ohm 20 kV high-voltage cable assemblies in multiple connector configurations, including 20 kV Plug to 10 kV Plug, 20 kV Plug to SHV Plug, 20 kV Plug to MHV Male, and 20 kV Plug to 20 kV Plug. Choose from RG213/U, RG214/U, and RG393/U cable options.
Assemblies feature nickel-plated brass connector bodies and gold-plated contacts, with operating temperature ranges of −40°C to +80°C for RG213/U and RG214/U and −55°C to +200°C for RG393/U. Cable options are rated for a maximum operating voltage of 5,000 Vrms.
20 kV Plug to 10 kV Plug High-Voltage Cable Assemblies

50 Ohm high-voltage cable assemblies featuring a 20 kV plug to 10 kV plug configuration. Available with RG213/U, RG214/U, and RG393/U cable options.
View BM90491 Specifications
20 kV Plug to 10 kV Plug Cable Assembly RG213/U
Detailed Description
50 Ohm 20 kV plug to 10 kV plug cable assembly with RG213/U coax, single-shield construction, and an operating temperature range of −40°C to +80°C.
View BM90493 Specifications
20 kV Plug to 10 kV Plug Cable Assembly RG214/U
Detailed Description
50 Ohm 20 kV plug to 10 kV plug cable assembly with RG214/U coax, dual silver-plated copper shields, and an operating temperature range of −40°C to +80°C.
View BM90495 Specifications
20 kV Plug to 10 kV Plug Cable Assembly RG393/U
Detailed Description
50 Ohm 20 kV plug to 10 kV plug cable assembly with RG393/U coax, dual silver-plated copper shields, and an extended operating temperature range of −55°C to +200°C.
20 kV Plug to SHV Plug High-Voltage Cable Assemblies

50 Ohm high-voltage cable assemblies with a 20 kV plug to SHV plug configuration. Available with RG213/U, RG214/U, and RG393/U cable options.
View BM90507 Specifications
20 kV Plug to SHV Plug Cable Assembly RG213/U
Detailed Description
50 Ohm 20 kV plug to SHV plug cable assembly with RG213/U coax, single-shield construction, and an operating temperature range of −40°C to +80°C.
View BM90509 Specifications
20 kV Plug to SHV Plug Cable Assembly RG214/U
Detailed Description
50 Ohm 20 kV plug to SHV plug cable assembly with RG214/U coax, dual silver-plated copper shields, and an operating temperature range of −40°C to +80°C.
View BM90511 Specifications
20 kV Plug to SHV Plug Cable Assembly RG393/U
Detailed Description
50 Ohm 20 kV plug to SHV plug cable assembly with RG393/U coax, dual silver-plated copper shields, and an extended operating temperature range of −55°C to +200°C.
20 kV Plug to MHV Male High-Voltage Cable Assemblies

50 Ohm high-voltage cable assemblies with a 20 kV plug to MHV male connector configuration. Available models include RG213/U, RG214/U, and RG393/U cable options.
View BM90515 Specifications
20 kV Plug to MHV Male Cable Assembly RG213/U
Detailed Description
50 Ohm 20 kV plug to MHV male cable assembly with RG213/U coax, single-shield construction, and an operating temperature range of −40°C to +80°C.
View BM90518 Specifications
20 kV Plug to MHV Male Cable Assembly RG214/U
Detailed Description
50 Ohm 20 kV plug to MHV male cable assembly with RG214/U coax, dual silver-plated copper shields, and an operating temperature range of −40°C to +80°C.
View BM90520 Specifications
20 kV Plug to MHV Male Cable Assembly RG393/U
Detailed Description
50 Ohm 20 kV plug to MHV male cable assembly with RG393/U coax, dual silver-plated copper shields, and an extended operating temperature range of −55°C to +200°C.
20 kV Plug to 20 kV Plug High-Voltage Cable Assemblies

20 kV plug-to-plug cable assemblies for high-voltage interconnections requiring matching 20 kV interfaces. Available with RG213/U, RG214/U, and RG393/U cable options.
View BM92709 Specifications
20 kV Plug to 20 kV Plug Cable Assembly RG213/U
Detailed Description
50 Ohm 20 kV plug to 20 kV plug cable assembly with RG213/U coax, single-shield construction, and an operating temperature range of −40°C to +80°C.
View BM92711 Specifications
20 kV Plug to 20 kV Plug Cable Assembly RG214/U
Detailed Description
50 Ohm 20 kV plug to 20 kV plug cable assembly with RG214/U coax, dual silver-plated copper shields, and an operating temperature range of −40°C to +80°C.
View BM92713 Specifications
20 kV Plug to 20 kV Plug Cable Assembly RG393/U
Detailed Description
50 Ohm 20 kV plug to 20 kV plug cable assembly with RG393/U coax, dual silver-plated copper shields, and an extended operating temperature range of −55°C to +200°C.
High-Voltage Cable Assemblies and More
Need a different cable configuration or length? Bracke offers custom cable assembly solutions to meet specific application requirements.
Beyond high-voltage cable assemblies, explore RF couplers, power dividers, attenuators, connectors, switches, terminations, test accessories, and other RF and microwave components.
Browse our complete selection of precision RF adapters with operating frequencies up to 110 GHz.
Standard and custom cable assemblies available with numerous connector combinations and coaxial cable options.
Fixed, variable, high-power, and precision attenuators for RF and microwave applications.
Calibration standards, DC blocks, terminations, patch cords, and other RF test components.
Q&A
What 20 kV cable assembly configurations are available?
Available configurations include 20 kV Plug to 10 kV Plug, 20 kV Plug to SHV Plug, 20 kV Plug to MHV Male, and 20 kV Plug to 20 kV Plug assemblies.
What coaxial cable options are available?
Depending on the connector configuration, assemblies are available with RG213/U, RG214/U, and RG393/U 50 Ohm coaxial cable.
What is the difference between the RG213/U, RG214/U and RG393/U options?
RG213/U uses bare copper conductors with a single shield, while RG214/U and RG393/U use silver-plated copper conductors with dual shields. RG393/U also features a PTFE dielectric and supports a wider operating-temperature range of −55°C to +200°C.
Are custom cable lengths available?
Yes. Cable assemblies are available in custom lengths, with the required cable length specified in inches as part of the model number. Standard cable-length tolerance is ±1.5% or 3/8 inch, whichever is greater.
What materials are used in the connectors?
The connectors feature nickel-plated brass bodies and gold-plated contacts. Insulator materials vary by connector type and include HDPE and PTFE.
How do I select the right high-voltage cable assembly?
Select the required connector configuration first, then choose from RG213/U, RG214/U, or RG393/U based on shielding, operating-temperature, and application requirements. Contact Bracke for assistance selecting a model for your application.
When you choose Bracke Manufacturing, you’re partnering with a trusted leader in precision RF and microwave connectivity. Guided by industry veteran Lawrence Pasternack, Bracke delivers expertly engineered products that combine precision, reliability, and performance for demanding test and measurement environments.
For more information, call (949) 756-1600 or email sales@brackemfg.com. Request our free catalog or contact us for technical support and custom RF solutions.
Didn’t find what you were looking for?
Click below to explore Bracke’s extensive lineup of RF and microwave components and accessories.
Browse our wide selection of RF and Microwave products available in our online store. Most orders placed by 4pm PST ship the same day.